Products
2400 NGC
568
2200
541-400
541-008
541/542-009
541-030
542-030
|
|
 |
|
541-400 Electronic
|
|
Valve Material
|
Glass-Filled Noryl®
|
|
Regeneration Initiation
|
Time Clock (Interval 130 Days)
Demand (10099,900 gallons, 100999,900 liters)
Demand with Day Override (130 Days)
|
|
Flow Rate @ 40 psi (2.76 bar) Inlet
Continuous @ 15 psi (1.03 bar) Drop
Peak @ 25 psi (1.72 bar) Drop
Backwash, Softener @ 40 psi (2.76
bar) Drop
Backwash, Filter @ 40 psi (2.76 bar)
Drop
|
System*
18.6 gpm/70.4 lpm
24.0 gpm/90.8 lpm
5.0 gpm/18.9 lpm
8.2 gmp/31.0 lpm
|
|
Service
|
Cv 4.8, Kv 4.1
|
|
Backwash (Softener)
|
Cv 0.8, Kv 0.7
|
|
Backwash (Filter)
|
Cv 1.3, Kv 1.1
|
|
|
Regeneration
|
2, 3, 5, or 7 Cycles
|
|
Adjustable
|
1-Minute Increments (099 Minutes per Cycle)
|
|
2 Cycle
|
3 Cycle
|
5 Cycle
|
7 Cycle
|
|
Backwash
Service
|
Brine/Slow rinse
Service
|
Backwash
Brine/Slow Rinse
Fast Rinse
Service
|
Backwash
Brine/Slow Rinse
Fast Rinse
Purge/Time Brine Refill
Service
|
|
|
|
Connections/Dimensions
|
|
|
Tank Connection
Inlet/Outlet
Riser Connection
Drain Connection
Brine Line Connection
|
2 1/2"8 NPSM
1 1/2"16UN-2A
13/16" or 1.050"
1/2" NPT
1/4" NPT
|
|
|
Ratings
|
|
|
Electrical Rating
|
24V, 120V, 240V AC
50 Hz, 60 Hz
|
|
Operating Pressure
|
20 psi120 psi/1.37 bar8.28 bar
|
|
Hydrostatic Test Pressure
|
600 psi/41.4 bar
|
|
Operating Temperature
|
35°F120°F/2°C48°C
|
|
|
Options
|
|
|
BWFC Available (gpm)
|
1.6, 2.0, 2.2, 3.0, 3.5, Adjustable
|
|
Auxiliary Relay
|
24V AC (100MA)
|
|
Fitting Kits
|
3/4" Copper Tube (Sweat)
1" Copper Tube (Sweat)
3/4" NPT Female Adapter
3/4" BSP-PL Female Adapter
3/4" 90° Elbow (Sweat)
1" Male Adapter
1" BSP-PL Male Adapter
|
|
Upper Collector
|
|
|
|