Erie Water Treatment Controls
 
 
 

Products
2400 NGC
568
2100D
2100T
541-400
541-008
541/542-009
541-030
542-030

 

 

 

 

 

 

 

 

 

 

 

541-008 Time Clock

Valve Material

Glass-Filled Noryl®

Regeneration Initiation

Time Clock (12 Day)

Flow Rate @ 40 psi (2.76 bar) Inlet
    Continuous @ 15 psi (1.03 bar) Drop
    Peak @ 25 psi (1.72 bar) Drop
    Backwash, Softener @ 40 psi (2.76 bar) Drop

System*
18.6 gpm/70.4 lpm
24.0 gpm/90.8 lpm
5.0 gpm/18.9 lpm

Service

Cv 4.8, Kv 4.1

Backwash (Softener)

Cv 0.8, Kv 0.7


Regeneration

5 Cycles

Adjustable

5-Minute Increments

5 Cycle

Backwash
Brine/Slow Rinse
Fast Rinse
Service


Connections/Dimensions

 

Tank Connection
Inlet/Outlet
Riser Connection
Drain Connection
Brine Line Connection

2 1/2"–8 NPSM
1 1/2"–16UN-2A
13/16" or 1.050"
1/2" NPT
1/4" NPT


Ratings

 

Electrical Rating

24V, 120V, 240V AC
50 Hz, 60 Hz

Operating Pressure

20 psi–120 psi/1.37 bar–8.28 bar

Hydrostatic Test Pressure

600 psi/41.4 bar

Operating Temperature

35°F–120°F/2°C–48°C


Options

 

BWFC Available (gpm)

1.6, 2.0, 2.2, 3.0, 3.5

Fitting Kits

3/4" Copper Tube (Sweat)
1" Copper Tube (Sweat)
3/4" NPT Female Adapter
3/4" BSP-PL Female Adapter
3/4" 90° Elbow (Sweat)
1" Male Adapter
1" BSP-PL Male Adapter

Auxiliary Circuit

125/250V AC (10A)

Upper Collector

 

 

*Valve mounted on 10" tank with distributor system.